PARKER-HANNIFIN CORPORATION | 18565 |
NAVAL SEA SYSTEMS COMMAND | 53711 |
OVERALL WIDTH | 9.070 INCHES MINIMUM AND 10.030 INCHES MAXIMUM |
BODY THICKNESS | 0.693 INCHES MINIMUM AND 0.759 INCHES MAXIMUM |
DESIGN TYPE | REUSABLE |
BODY OVERALL LENGTH | 17.970 INCHES MINIMUM AND 18.030 INCHES MAXIMUM |
FILTERING MEDIA DESIGN | CRIMPED 1ST FILTERING MEDIA RESPONSE |
FILTERING MEDIA DESIGN | MESH 2ND FILTERING MEDIA RESPONSE |
SPECIAL FEATURES | ELECTROMAGNETIC INTERFERENCE GASKET; 16 FASTENER HOLES; ALUMINUM ALLOY,QQ-A-359,ALLOY 3003,H14 FLAT GRILLES ON BOTH SIDES |
MATERIAL | ALUMINUM ALLOY 5056 FILTERING MEDIUM |
MATERIAL | ALUMINUM ALLOY 6063 FRAME |
MATERIAL DOCUMENT AND CLASSIFICATION | QQ-A-200/9 FED SPEC SINGLE MATERIAL RESPONSE FRAME |
SURFACE TREATMENT | CHROMATE FILTERING MEDIUM |
SURFACE TREATMENT | CHROMATE FRAME |
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | MIL-C-5541 MIL SPEC SINGLE TREATMENT RESPONSE FILTERING MEDIUM |
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | MIL-C-5541 MIL SPEC SINGLE TREATMENT RESPONSE FRAME |
STYLE DESIGNATOR | RECTANGULAR (INCL SQUARE) |
A replaceable device designed to remove dust, pollen or other foreign matter from the air passing through it. The removal of particles is accomplished by porous fibrous or shredded material (metallic or nonmetallic) which is loosely woven or matted and confined in a frame or retained between perforated sheets of firmer material. It is designed to fit into air conditioners, ventilation systems, hot air furnaces, and electrical and electronic cabinets or housings. It may have facilities for radio frequency/electromagnetic interference shielding. The filter may be cleaned by the use of compressed air, blown through the filter element, or by using water and a suitable detergent for cleaning purposes which would extend the life of the filter. |